产品展厅 收藏该商铺

您好 登录 注册

当前位置:
美国布鲁克海文仪器公司>技术文章>测量应用案例-20220103

技术文章

测量应用案例-20220103

阅读:112          发布时间:2022-1-25

文献名: Rapid, on-site, and sensitive detection of aflatoxin M1 in milk products by using time-resolved fluorescence microsphere test strip

作者 Miao Li a , Haiming Wang b , Jiadi Sun a , Jian Ji a , Yongli Ye a , Xin Lu a , Yinzhi Zhang a , Xiulan Sun a

a State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, Jiangsu, 214122, PR China

b Guangzhou GRG Metrology & Test Co., Ltd, Guangzhou, 510630, PR China

摘要: Aflatoxin M1 (AFM1), a frequently occurring mycotoxin in milk and dairy products, causes acute and chronic poisoning. In this study, we developed a time-resolved fluorescence microsphere immunochromatographic test strip (TRFM–ICTS) combined with ultraviolet light for the rapid and quantitative detection of AFM1 in milk and its products. Polystyrene microspheres enclosing time-resolved fluorescent europium (III) [Eu(III)-TRFM] were prepared as a label and then conjugated to a monoclonal antibody. Pre-incubation was introduced for competitive recognition. Under optimal conditions, TRFM–ICTS had a linear range of 0.05–2.0 ng/mL with a 50% inhibitory concentration (IC50) of 0.204 ng/mL, which was nearly five–fold lower than those of ICTS in a traditional structure with traditional pretreatment (IC50 = 1.10 ng/mL). This test strip enhanced the sensitivity from 0.3 ng/mL (by using gold nanoparticles-strip method previously reported) to 0.019 ng/mL (by using this TRFM–ICTS method). The improved sensitivity may be due to the detection signals of immunoassay probes (with each fluorescence microsphere coupled with numbers of antibodies). TRFM–ICTS exhibited good recoveries ranging from 84.6% to 119.0% with a coefficient of variation (CV) lower than 8.31% in spiked samples, including milk powder, ultrahigh-temperature (UHT) and pasteurized milk. The results obtained using TRFM–ICTS were consistent with those obtained by ultrahigh–performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) during testing of real milk samples. In addition, TRFM–ICTS has a longer storage period, which basically meets the needs of the commercial market. Owing to its high sensitivity and practicability, the proposed TRFM–ICTS can be used as a sensitive, simple, rapid, and versatile method for the quantitative detection of AFM1 in milk.

关键词: Aflatoxin M1 ; Time-resolved fluorescence microspheres ; Immunochromatographic test strip ; Milk ; Sensitivity

收藏该商铺

登录 后再收藏

提示

您的留言已提交成功!我们将在第一时间回复您~

对比框

产品对比 产品对比 联系电话 二维码 意见反馈 在线交流

扫一扫访问手机商铺
010-62081908
在线留言