![]() | 德国朗博中国技术服务中心 |

19916557244
GA2730
阅读:3505发布时间:2018-1-17
HYGIENIC MEASUREMENT IN EXPLOSIVE ENVIRONMENTS
The resistance thermometer GA2730 Minitherm of LABOM has a matching range of thermowells for hygienic temperature measurement and is approved for use in explosive environments. In addition the Pt100 element meets the SIL2 safety requirements of EN 61508 for functional safety. The unique combination of equally high hygienic and safety standards qualifies the type series GA2730 Minitherm for the thermowell system HP1200 for demanding measurement tasks in the fields of pharmaceutics, biotechnology and food industry.
The HIT thermowell system for hygienic invasive temperature measurement (HIT) is welded orbitally in a process pipe section. The neck tube with the Pt100 sensor of the resistance thermometer can thus be assembled and disassembled without any interruption of the process. The invasive measurement method enables a particularly fast responding measurement. The GA2730-Minitherm sensor is also available with a G3/8 sensor port which is compatible with protective sleeves of other manufacturers.
Due to its intrinsically safe design the resistance thermowell Minitherm can also be used in explosive gas atmospheres zone 1 and 2 and dust atmospheres zone 21 and 22. Compliance with the requirements for SIL2 safety functions of electrical system ensures that the thermometer also works reliably in combination with appropriate transducers.
以上信息由企业自行提供,信息内容的真实性、准确性和合法性由相关企业负责,化工仪器网对此不承担任何保证责任。 温馨提示:为规避购买风险,建议您在购买产品前务必确认供应商资质及产品质量。